Product Description
The LXLG series horizontal vane wheel water meter (also known as Woltmann type) is the most widely used mechanical flow meter in agricultural irrigation. Its internal vane rotates like a water wheel as water flows axially through the meter, driving a gear train that accumulates the volume on a mechanical register.
Designed specifically for the challenging conditions of irrigation, this meter tolerates small amounts of sand, weeds, and other impurities commonly found in open water sources. It features low pressure loss, high flow capacity, and a removable measuring mechanism for easy maintenance without breaking the pipeline.
WINMETER offers the full range from DN50 to DN300, covering applications from small farms to large irrigation districts.
Key Features
- Designed for Agricultural Irrigation: Suitable for river, canal, well, lake water and reclaimed water irrigation.
- Can be Used as Sewage Water Meter: Durable construction allows metering of agricultural wastewater and reclaimed water.
- Removable Mechanism: The internal measuring unit can be replaced without removing the meter body from the pipeline – easy maintenance.
- Anti‑Blockage Design: Special vane wheel structure resists wrapping by weeds, sand, and debris.
- High Flow Capacity: Horizontal vane wheel design ensures low pressure loss and high flow rates up to DN300.
- Long Service Life: Ductile iron body with epoxy coating, metal cover, wear‑resistant components.
- Hermetically Sealed Register: Copper case prevents fogging, ensures clear long‑term reading.
- Pulse Output Optional: Ready for remote reading (reed switch / Hall sensor) to connect with SCADA or IoT systems.
Working Principle
Water enters the meter axially, passes through a flow straightener, and drives a horizontally mounted vane wheel. The rotational speed of the vane is proportional to the flow velocity. Through a gear reduction mechanism, the rotation is transmitted to a mechanical register, displaying the total volume passed.
Technical Specifications
| Parameter | Details |
|---|---|
| Model | LXLG-50 to LXLG-300 |
| Nominal Diameter | DN50 / DN65 / DN80 / DN100 / DN125 / DN150 / DN200 / DN250 / DN300 |
| Overload Flow (Q4) | 31.25 - 1250 m³/h (see flow table) |
| Permanent Flow (Q3) | 25-1000 m³/h (see flow table) |
| R‑ratio | R50 / R80 optional (acc. to ISO 4064) |
| Accuracy | Cold water: • Low zone (Q1 ≤ Q < Q2): ±5% • High zone (Q2 ≤ Q ≤ Q4): ±2% Hot water: • Whole range: ±3% (≤90°C) |
| Temperature Class | T50 (≤50°C) / T90 (≤90°C) optional |
| Pressure Rating | PN10 / PN16 optional |
| Pressure Loss | ΔP ≤ 63 kPa at Q3, meets ΔP25 class |
| Installation | Horizontal (register facing up) |
| Connection | Flanged (GB/T 9119 / ISO 7005 / ANSI / DIN optional) |
| Body Material | Ductile iron with epoxy coating |
| Vane Material | Reinforced nylon / wear‑resistant engineering plastic |
| Register | Dry‑dial, copper case, anti‑fog |
| Minimum Reading | 0.01 m³ (all sizes) |
| Maximum Reading | 9,999,999 m³ (all sizes) |
| Protection Class | IP68 optional (submersible) |

Flow Rate Parameters
| Model | Unit | LXLC-50 | LXLC-65 | LXLC-80 | LXLC-100 | LXLC-125 | LXLC-150 | LXLC-200 | LXLC-250 | LXLC-300 |
|---|---|---|---|---|---|---|---|---|---|---|
| Nominal Diameter | mm(inch) | 2" | 2-1/2" | 3" | 4" | 5" | 6" | 8" | 10" | 12" |
| Overload Flow (Q4) | m³/h | 31.25 | 50 | 78.75 | 125 | 200 | 312.5 | 500 | 787.5 | 1250 |
| Permanent Flow (Q3) | m³/h | 25 | 40 | 63 | 100 | 160 | 250 | 400 | 630 | 1000 |
| Transitional Flow (Q2) | m³/h | 0.5 | 0.8 | 1.26 | 2 | 3.2 | 5 | 8 | 12.6 | 7.5 |
| Minimum Flow (Q1) | m³/h | 0.3125 | 0.5 | 0.787 | 1.25 | 2 | 3.125 | 5 | 7.875 | 12.5 |
| Minimum Reading | m³ | 0.001 | 0.001 | 0.001 | 0.001 | - | 0.01 | 0.01 | 0.01 | 0.01 |
| Maximum Reading | m³ | 9,999,999 | 9,999,999 | 9,999,999 | 9,999,999 | 99,999,999 | 99,999,999 | 99,999,999 | 99,999,999 | 999,999,999 |
| Temperature Class | T/°C | T50/T90 | ||||||||
| Pressure Rating | MPa | 1.0/1.6 | ||||||||
| Pressure Loss Class | MPa | △P63 | ||||||||
| Installation Direction | - | Horizontal | ||||||||

Dimensions & Flange Details

| Model | DN (mm) | Inch | Length L (mm) | Height H (mm) | Flange OD D (mm) | Bolt Circle D1 (mm) | Bolt Holes |
|---|---|---|---|---|---|---|---|
| LXLG-50 | 50 | 2" | 200 | 253 | 165 | 125 | 4‑M16 |
| LXLG-65 | 65 | 2½" | 200 | 268 | 185 | 145 | 4‑M16 |
| LXLG-80 | 80 | 3" | 225 | 284 | 200 | 160 | 8‑M16 |
| LXLG-100 | 100 | 4" | 250 | 295 | 220 | 180 | 8‑M16 |
| LXLG-125 | 125 | 5" | 250 | 310 | 250 | 210 | 8‑M16 |
| LXLG-150 | 150 | 6" | 300 | 339 | 285 | 240 | 8‑M20 |
| LXLG-200 | 200 | 8" | 350 | 382 | 340 | 295 | 8‑M20 (PN10) / 12‑M20 (PN16) |
| LXLG-250 | 250 | 10" | 400 | 433 | 395 | 350 | 8‑M20 (PN10) / 12‑M24 (PN16) |
| LXLG-300 | 300 | 12" | 450 | 483 | 445 | 400 | 8‑M20 (PN10) / 12‑M24 (PN16) |
*Note: Flanges according to GB/T 9119 PN10/PN16. ANSI, DIN options available on request.*
Applications
- Mainline agricultural irrigation metering
- Pump station discharge monitoring
- River, lake, and reservoir water intake
- Farm water management
- Aquaculture supply
- Reclaimed water / wastewater irrigation
- Large irrigation district canals (DN250/DN300)
Selection Guide
1. Choose Diameter
Select based on your permanent flow rate (Q3). Recommended operating range: 70%‑100% of Q3.
DN250: Q3 = 630 m³/h → recommended 440‑630 m³/h
DN300: Q3 = 1000 m³/h → recommended 700‑1000 m³/h
2. Choose Accuracy (R‑ratio)
R50: standard
R80: higher sensitivity for low flow applications
3. Choose Temperature Class
T50: cold water ≤50°C
T90: hot water ≤90°C (accuracy ±3%)
4. Choose Material & Pressure
Standard: ductile iron + epoxy, PN10
High pressure: PN16
Corrosive media: bronze / stainless steel body
5. Choose Function
Basic: mechanical register only
Pulse output: reed switch / Hall sensor for remote reading
Smart: LCD + NB‑IoT / 4G for real‑time monitoring
6. Choose Flange Standard
Default: GB/T 9119 PN10/PN16. ANSI 150LB, DIN etc. available.
7. Check Installation Conditions
Straight pipe upstream ≥10×DN, downstream ≥5×DN
Flow direction arrow must match
Install a strainer if water contains large debris (especially for DN250/DN300)
Installation & Maintenance
1. Installation Tips:
- Flush pipeline thoroughly before installation.
- Install shut‑off valves before and after the meter.
- Mount horizontally with register facing upward.
- For large sizes (DN250, DN300), use lifting equipment and ensure pipe alignment to avoid stress on the meter body.
2. Maintenance:
- Removable mechanism: The internal measuring unit can be extracted without removing the meter body – easy cleaning or replacement.
- Periodically check register operation.
- Close valves if meter is unused for long periods.
- Protect from freezing in winter (drain or insulate).
- Clean glass if fogging occurs.
Packaging & Shipping
- Packaging: Bubble wrap + wooden crate (all large sizes DN250/DN300 in strong wooden crates).
- Delivery time: Stock items 48h; custom orders (DN250/DN300) 7‑15 working days.
- Shipping: DHL, FedEx, sea freight, or truck (DN250/DN300 recommended by truck).
FAQ
Q: What is the difference between a horizontal vane wheel meter and a standard water meter?
A: The horizontal vane (Woltmann) meter has an axial flow design, offering very low pressure loss and high flow capacity. Its vane shape is less sensitive to debris, making it ideal for irrigation.
Q: Can it be used in muddy water?
A: Yes, it tolerates sand and small fibers. For extremely muddy water, a pre‑filter or settling tank is recommended to prolong life.
Q: Can it really be used for sewage water?
A: It is suitable for agricultural wastewater and reclaimed water due to its wear‑resistant materials and anti‑clog design. For aggressive industrial effluent, an electromagnetic meter is recommended.
Q: What is the advantage of a removable mechanism?
A: You can service or replace the internal measuring part without dismantling the meter body – minimal downtime and easy maintenance.
Q: What is the difference between cold water and hot water versions?
A: Cold water (T50) ≤50°C, accuracy ±2%/±5%; hot water (T90) ≤90°C, accuracy ±3% over whole range.
Q: Does it need power?
A: Basic mechanical version needs no power. Pulse output and smart versions require external power or battery.
Q: How heavy are DN250 and DN300 meters?
A: DN250: ~60‑80kg; DN300: ~80‑100kg. Lifting equipment is necessary during installation. WINMETER can provide on‑site guidance if needed.
Customer Factory Visit

Support Factory Customization





international certifications

Hot Tags: Agricultural Irrigation Bulk Water Meter, China Agricultural Irrigation Bulk Water Meter manufacturers, suppliers, factory, Agricultural Irrigation Bulk Water Meter, Bulk Ultrasonic Water Meter, bulk water meter, Large Diameter Flanged Compound Water Meter, Sandwich Type Ultrasonic Water Meter, Vertical WS Bulk Woltmann Water Meter