Product Overview
The Card‑Type Ultrasonic Flow Meter is specially developed for agricultural irrigation, landscaping, and water resource monitoring. It has no internal moving parts or flow obstruction, meaning zero pressure loss and long‑term reliability even with sandy or debris‑laden water. Using advanced ultrasonic transit‑time technology, it deliver accurate, stable measurement with easy installation and a sleek, compact design.
Key advantages for irrigation:
No pressure drop – saves pumping energy.
No clogging – works with muddy or partially treated water.
Low maintenance – no mechanical parts to wear or replace.
IP65 rated – can be installed outdoors or in meter pit.

Measurement Principle & Key Feature
How It Works (Transit‑Time Difference)
Two ultrasonic transducers alternately transmit and receive signals. The meter measures the time difference between downstream and upstream propagation, then calculates instantaneous flow rate and total volume. The system consists of a flow sensor (measures volume) and a computin unit (calculates flow rate and totalizer).
Design & Functional Feature
| Feature | Benefit |
|---|---|
| High‑stability transducers | Imported piezoelectric ceramic wafers ensure consistent performance and high accuracy. |
| Self‑diagnosis function | If communication fails, battery is low, or tampering is detected, an error code is displayed. Data is saved automatically until the fault is cleared. |
| Remote reading or centralized control | Built‑in RS485 / M‑BUS interface allows integration with Modbus RTU or T188 protocols. |
| IP68 protection | Dust‑tight and protected against water jets – suitable for outdoor irrigation environments. |
| Tamper‑resistant design | Prevents unauthorized disassembly or interference. |
| Flexible installation | Display can be rotated for easy reading; works horizontally or vertically (with proper pipe filling). |

Technical Specifications
| Parameter | Value |
|---|---|
| Nominal diameter (DN) | DN50, DN65, DN80, DN100 |
| Maximum flow (Qs) | 18.75 / 31.25 / 50 / 75 m³/h |
| Permanent flow (Qp) | 15 / 25 / 40 / 60 m³/h |
| Minimum flow (Q1 ) | 1.5 / 2.5 / 4 / 6 m³/h |
| Measured medium | Water / homogeneous liquids |
| Accuracy class | Class 2 |
| Turn‑down ratio | 10:1 |
| Pressure loss | < 0.025 MPa |
| Nominal pressure | 1.0 MPa |
| Keypad | Push button or auto‑cycling display |
| Protection class | IP65 |
| Power supply | 3.6V lithium battery / dual‑power (battery + external) |
| Communication | RS485 / M‑BUS |
| Protocol | Modbus RTU, T188 |
| Installation orientation | Horizontal or vertical (see guidelines below) |
Note: The provided table lists two columns as "Qp(m³/h)" for both common and minimum flow. We have interpreted the last column as minimum flow. Please confirm with factory.
Flow Range Table (for quick reference)
| DN (mm) | Qs (m³/h) | Qp (m³/h) | Qmin (m³/h) |
|---|---|---|---|
| 50 | 18.75 | 15 | 1.5 |
| 65 | 31.25 | 25 | 2.5 |
| 80 | 50 | 40 | 4.0 |
| 100 | 75 | 60 | 6.0 |

Installation Guidelines
General Requirements
Flush the pipeline thoroughly before installation to remove sand, debris, and sealing tape.
Flow direction must match the arrow on the meter body.
Straight pipe lengths: Upstream ≥10D, downstream ≥5D (D = meter diameter).
Install strainers and shut‑off valves before and after the meter for maintenance.
Orientation Rules (Critical for Accuracy)
| Installation Type | Requirement |
|---|---|
| Horizontal pipe | Display must face upward. If rotated sideways, the higher transducer may collect air bubbles, causing error. |
| Vertical pipe | Only allowed when flow is upward (rising pipe). Downward flow may cause partial filling and inaccurate measurement. |
| U‑shaped pipe | Install the meter at the lowest point of the U. High points accumulate air, which will disrupt measurement. |
Display & Communication
LCD Display Content (Cyclic)
| Parameter | Example |
|---|---|
| Instantaneous flow rate | 0.000 m³/h |
| Total volume | 00000000 m³ |
| Meter address | 00000001 |
| Pipe diameter | DN80 |
| Operating time | 00000‑00 Hours |
RS485 / M‑BUS Wiring
Terminal connections: A (+), B (-), and optional ground (GND).
Use twisted‑pair shielded cable for long distances.
Default protocol: Modbus RTU (baud rate configurable) or T188 (Chinese utility standard).
The meter supports remote reading, centralized control, and integration with irrigation management systems.

Quality Assurance & Service Support
Warranty Coverage
One year from date of delivery against manufacturing defects.
Free repair or replacement for products that fail due to material or workmanship.
Exclusions (not covered)
Broken seals, tampering, or unauthorized opening.
Damage from extreme weather (flooding, freezing), chemical corrosion.
Failure to flush pipeline before installation (debris damage).
Physical damage (cables torn, housing cracked by impact).
Battery replacement by non‑authorized personnel – contact factory for battery service.
Note: When low battery warning appears, do not attempt to replace the battery yourself. Please contact our support team.
Ordering Information & Contact
How to order
Please specify:
Model: Card‑Type Ultrasonic Flow Meter for Irrigation
Size: DN50 / DN65 / DN80 / DN100
Power: 3.6V lithium battery / dual‑power
Communication: RS485 (Modbus) / M‑BUS (T188)
Cable length (if remote display needed)
Options: Custom label, extra strainer, solar power kit
Minimum order quantity: 1 unit (standard models)
Lead time: 5–10 days for stock sizes; 15–20 days for customized orders
Packaging: Individual carton with foam protection
Company Profile
Zhisheng Meijia Intelligent Technology (Shandong) Co., Ltd. (WINMETER) has over 16 years of experience in R&D and manufacturing of smart water meters, ultrasonic meters, AMI/AMR systems, and IoT solutions. We export to Asia, Africa, the Middle East, Latin America, and Europe. Annual production capacity exceeds 1 million meters.
Get in Touch
For technical support or a quote, contact us directly:
Email: shawndu@winmegameter.com
WhatsApp: +86 15330027467
Website: www.winwatermeter.com
Factory address: Shandong Province, China (full address upon request)
Office hours: Mon–Fri 8:30–17:30 (GMT+8), Sat 8:30–12:00
Client On-site Visit
Within one year of use, if the meter is installed properly, operates under normal flow conditions, and malfunctions due to internal parts damage caused by product quality (excluding freezing damage), the manufacturer shall be responsible for repair or replacement provided that the lead seal is intact and effective.

Custom Manufacturing Available


Worldwide Accreditation

Hot Tags: Agricultural Irrigation Card‑Type Ultrasonic Flow Meter, China Agricultural Irrigation Card‑Type Ultrasonic Flow Meter manufacturers, suppliers, factory, Stainless Steel Bulk Industrial Water Meter, Turbine WPD Bulk Woltmann Water Meter, Horizontal WPH Bulk Woltmann Water Meter, Bulk Ultrasonic Water Meter, Vertical WS Bulk Woltmann Water Meter, Agricultural Irrigation Bulk Water Meter